Ballast

High-Frequency 1-10 Dimming Ballast

2ft HF-Ballast II for TL-D lamps T8 1-10v High-frequency electronic dimming ballast, using the analog protocol (1-10 V) for TL-D lamps
Interface 1-10V
Rated Number of Lamps 1 piece
Rated Ballast-Lamp Power 18 W
Rated Lamp Type TL-D
Application code EII
Line Voltage 220-240 V
Line Frequency 50/60 Hz
Housing L 360x30x21
Ignition Method Programmed Start
Lifetime 90% surv.@T caselife 50000 hr
Energy Efficiency Index A1
T-ignition 0 (min), 50 (max) °C
T-ambient -20 (min), 50 (max) °C
T-storage -25 (min), 80 (max) °C
Part Number BALH/F18

4ft HF-Ballast II for TL-D lamps T8 1-10v High-frequency electronic dimming ballast, using the analog protocol (1-10 V) for TL-D lamps
Interface
1-10V
Rated Number of Lamps 1 piece
Rated Ballast-Lamp Power 36 W
Rated Lamp Type TL-D
Application code EII
Line Voltage 220-240 V
Line Frequency 50/60 Hz
Housing L 360x30x21
Ignition Method Programmed Start
Lifetime 90% surv.@T caselife 50000 hr
Energy Efficiency Index A1
T-ignition 0 (min), 50 (max) °C
T-ambient 10 (min), 50 (max) °C
T-storage -25 (min), 80 (max) °C
Part Number BALH/F38

5ft HF-Ballast II for TL-D lamps T8 1-10v High-frequency electronic dimming ballast, using the analog protocol (1-10 V) for TL-D lamps
Interface
1-10V
Rated Number of Lamps 1 piece
Rated Ballast-Lamp Power 58 W
Rated Lamp Type TL-D
Application code EII
Line Voltage 220-240 V
Line Frequency 50/60 Hz
Housing L 360x30x21
Ignition Method Programmed Start
Lifetime 90% surv.@T caselife 50000 hr
Energy Efficiency Index A1
T-ignition 0 (min), 50 (max) °C
T-ambient 10 (min), 50 (max) °C
T-storage -25 (min), 80 (max) °C
Part Number BALH/F58

High Frequency DSI Dimmable Balast

2ft HF-Ballast for TL-D lamps T8 DSI High-frequency electronic dimming ballast, using the digital protocol for TL-D lamps
Interface DSI
Rated Number of Lamps 1 piece
Rated Ballast-Lamp Power 18 W
Line Voltage 220-240 V
AC Voltage Range 198-264 V
Line Frequency 50/60 Hz
Over voltage Protection 320 V AC, 1 h
Typ. Power Input on Standby < 0.2 W
Protective Hot Restart 0.5 s for AC / 0.2 s for DC
Nominal Life up to 100,000 hr (at ta 50°C)
Energy Efficiency Index A1 BAT
Dimming Range 1 - 100%
T-ambient -25 (min), 70 (max) °C
Lamp start Possible From 1%
Operating Frequency ~ 40 - 130 kHz
Type of protection IP20
Housing L 360x30x21
Part Number BALH/F18DIG

4ft HF-Ballast for TL-D lamps T8 DSI High-frequency electronic dimming ballast, using the digital protocol for TL-D lamps
Interface DSI
Rated Number of Lamps 1 piece
Rated Ballast-Lamp Power 36 W
Line Voltage 220-240 V
AC Voltage Range 198-264 V
Line Frequency 50/60 Hz
Over voltage Protection 320 V AC, 1 h
Typ. Power Input on Standby < 0.2 W
Protective Hot Restart 0.5 s for AC / 0.2 s for DC
Nominal Life up to 100,000 hr (at ta 50°C)
Energy Efficiency Index A1 BAT
Dimming Range 1 - 100%
T-ambient -25 (min), 70 (max) °C
Lamp start Possible From 1%
Operating Frequency ~ 40 - 130 kHz
Type of protection IP20
Housing L 360x30x21
Part Number BALH/F38DIG

Low Frequency Dimmable Balast

2ft Low-Frequency Ballast T12 Magnetic chokes for fluorescent lamps
Ballast type Switch start
Rated Number of Lamps 1 piece
Rated Ballast-Lamp Power 18 W
Line Voltage 220-240 V
Line Frequency 50/60 Hz
Nominal Life 100,000 hr (at tw = 130 °C)
Energy Efficiency Index B2
Dimming Range 1 - 100%
Max. winding temperature tw 130 °C
Housing L 152x41x31
Part Number BAL18

4ft Low Frequency Ballast T12 Magnetic chokes for fluorescent lamps
Ballast type Switch start
Rated Number of Lamps 1 piece
Rated Ballast-Lamp Power 36 W
Line Voltage 220-240 V
Line Frequency 50/60 Hz
Nominal Life 100,000 hr (at tw = 130 °C)
Energy Efficiency Index B2
Dimming Range 1 - 100%
Max. winding temperature tw 130 °C
Housing L 152x41x31
Part Number BAL38